Multichem NB

Third party, single elevated level, liquid stable quality control material to monitor the precision of laboratory testing procedures for Bilirubin and Theophylline Assays.

Resources: BROCHURE |CATALOGUE

Product Description

Technopath’s Multichem NB (Neonatal Bilirubin) Control is intended for use as a third party, single level, liquid stable quality control material to monitor the precision of laboratory testing procedures for Bilirubin and Theophylline Assays.

An important patient population is Neonates, where a requirement has been identified for testing conditions associated with Neonatal hyperbilirubinemia. The product also contains Theophylline, a therapeutic drug that is given to Neonates to improve lung capacity and where it would be required to monitor for toxicity risk. Caffeine is a listed analyte that is added gravimetrically, and this has a clinical function as the primary treatment of the breathing disorders apnea of prematurity.

Another important population is with any patient that has liver failure. It is important if  the laboratory tests hyperbilirubinemia patient samples that they analyze QC regularly to monitor this range to ensure accuracy and precision at these elevated  levels.

The requirement for a high concentration of Bilirubin presents a conflict for consolidation of multi-analytes. This means that not only is a separate paediatric control required, but a control matrix that is treated with antioxidants to inhibit the oxidation of Bilirubin. The application of the most appropriate measures to reduce the effect of oxidation on the high levels of Bilirubin in the Control have been researched to ensure that open vial and closed stability is maintained.

Multichem NB Control is designed as a single level, liquid stable frozen product. The product will typically be run as a supplementary high level control, in conjunction with at least one of the Multichem Serum Control levels, (S or S Plus) to provide a minimum of 2 levels of control to allow assay system performance monitoring within the analytical ranges. It will be run after reagent calibration and at a frequency dictated by laboratory QC procedures and reagent / instrument manufacturer instructions. The product should be treated the same as patient specimens and run in accordance with the instructions accompanying the instrument, kit or reagent being used. The control is to be stored at -20°C to –80°C and thawed as per IFU prior to use. The product is to be stored at 2 to 8°C between use.

Benefits

  • Satisfies regulatory guidelines for use of independent controls
  • Concentrations targeted at clinically relevant values
  • Long shelf life extends lot availability
  • Track product performance with IAMQC

Features

  • Frozen, Liquid stable, single level control
  • 14 days open vial stability once thawed and stored at 2 to 8 degrees
  • 36 months shelf life once stored at -20 to -80°C degrees
  • Third party independent quality control
  • Optimised and assayed for major IVD platforms
  • Human based materials used as part of manufacturing process
  • Mimics performance of commutable patient samples